PCB Assembly Cam-14 v2
2028778-003 | |
2028778-001 900995-004 | |
New | |
Diagnostic ECG | |
GE HealthCare | |
GE HealthCare | |
N/A | Outright |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Rigidity and flexible
- Good structural design
- Higher reliability and efficiency
- Great maintainability
Frequently purchased with this item
Product Overview
The Printed Circuit Board (PCB) Assembly Cam-14 HD is used in Diagnostic Electrocardiogram (ECG) machines. The CAM-14 acquisition module is intended to acquire the analog ECG signal, digitize it and transmit the signal to a host unit. The PCB (Printed Circuit Board) is assembled in the CAM-14 HD. The circuitry is designed to protect the host unit against the effects of cardiac defibrillator discharge to ensure recovery. CAM-HD module has 3 software pieces that need to be programmed to flash memory during the board assembly. Two of these pieces are programmed to the Atmel AT45DB041 Dataflash (U113), and the third to the on chip flash memory of the AT Tiny2313 (U121) chip. The PCB consists of IC’s, diodes, resistors, connectors, capacitors, ferrite bead, LED and transistors. The PCB is mounted using the provided screws. Cables are connected to the main PCB. Fasteners are used as connections to ground panes on PCB. The ECG signal input is isolated and defibrillation-proof only in conjunction with CAM14. It is being used in CASE, MS CARESCAPE™ Monitor B850, CardioSoft, UL Vivid S6, Stress Other, UL Voluson P8, Premium Carts Other, CT SYTEC 8000 1-Slice, MAC 5500 HD, ARC Aisys CardioSoft, CT CTe 1 – Slice, Supplies and other applications.
Compatible Products
CAM 14
CAM 14 v2
CAM 14 v2 (Product Code RNC and SK9)
Equivalent Item(s):
Below is more information on the equivalent item(s). Items without a hyperlink are listed for reference only and are not available for purchase online.
Equivalent Item(s) | Item Details |
---|---|
2028778-001 | PCB ASSY CAM14 V2 |
900995-004 | 900995-004 |
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.