Full Field Digital Mammography (FFDM) 1.1 Power Supply 2292162-2-H
2292162-2-H | |
Used | |
X-Ray | |
GE HealthCare | |
GE HealthCare | Exchange - Return Defective |
Core Exchange | |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Over Voltage Protection
- Over Temperature Protection
- High efficiency of more than 75%
- Multiple outputs
Product Overview
The Full Field Digital Mammography (FFDM) Power Supply assembly is used to provide regulated DC power supply to detectors. The assembly consists of a configurable AC-DC power supply and a Power Supply Control Board (PSCB). The power supply is a set of AC to DC switching converters that provides multiple DC outputs wherein the PSCB receives the voltages and passes it to the detector. This PSCB circuit monitors and controls the outputs from converters which provide a stable and smooth supply to the detector. The power supply has an internal fan with an airflow volume rate of 30 Cubic Feet per Minute (CFM) for cooling. The assembly has 5 different outputs: ARC Positive, ARC Negative, Analog Positive, Analog Negative and Logic and comes with required cables, connectors and appropriate labeling. This power supply assembly can be used in Revolution XRd and Seno Advantage systems. 2292162-2-H
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.