Detector Module Assembly T3455Dk 2296818-H
2296818-H | |
Used | |
PET/CT | |
GE HealthCare | |
GE HealthCare | |
N/A | Outright |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Field replacable Unit (FRU)
- Reliable, durable and highly advanced
- Complies IEC601 and UL2601
Product Overview
The detector module assembly T3455Dk consist of 8 detector units, a preamplifier board, and a T-bone. The positioning of units within a module is controlled by module gluing fixtures. The fixture holds the module mounting frame (t-bone) and the 8 detector units. The preamplifier board receive the high voltage from the high voltage power supply and distribute it to all the detectors units in the module. The output of the detector units is connected to a preamplifier board which converts the current signals from the PMTs (Photomultiplier Tubes) into a voltage signal and transmit them to the Raptor. This Detector module can be used with Discovery ST, Discovery ST (4 Slice), Discovery ST (8 Slice)and Discovery ST (16 Slice).
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.