Plug in Module Assembly MC RW with New Motion Amplifier
2336781-4-R | |
Refurbished | |
Ultrasound | |
Other Ultrasound | |
GE HealthCare | |
GE HealthCare | Exchange - Return Defective |
Core Exchange | |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Enhanced durability and reliability
- Good dimensional stability
- Interface with the Gantry Motion Control Amplifiers
- Motor control signal interface
Product Overview
The Plug in Module Assembly MC RW with New Motion Amplifier is used in Ultrasound and many other similar medical devices. It is comprised of a motion control carrier, AMC amplifier, faceplate, cable, screw, Loctite, nut, connector and washers. The board is to interface to the AMC Dx15CT8J motion control amplifier. The amplifier is a digital servo amplifier with general purpose and dedicated I/O and a CAN open interface. The amplifier CAN node ID and baud rate are to be configured over the CAN bus at the time of manufacture. In order to allow this, the amplifier node ID and baud rate DIP switches should all be set to “Off”. MCA Carrier assembly is to provide electrical signals and CAN communication interface between the electrical device peripherals and the motion control amplifier. All power supply connections are through backplane connector J14. Separate returns are brought into the board for each of the supplies, +48VDC motor power, +24VDC logic power, +12VDC CAN bus power, and +5VDC alignment light power. The MCA Carrier assembly may be shipped singly in a shipping container or in multiples by means of a larger shipping container. In both cases, the board is protected from ESD hazards. All shipping containers shall comply with the material and packing requirements.
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.