Quick Disconnect Assembly - 16 Channel Transmit
5184208-2-R | |
Refurbished | |
Magnetic Resonance Imaging (MRI) | |
GE HealthCare | |
GE HealthCare | |
N/A | Outright |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Possess strength and hardness
- Has good structural design
- Has a prolonged life
- Corrosion resistant, fire resistant and heat resistant
Product Overview
The 16 Channel Excite III Head Neck Spine System Cable in Magnetic Resonance Imaging (MRI) is used in 1.5T HDX 16CH SWCH UPG, Excite III LPCA-Bridge-Ped Assembly and other medical equipment's as applicable. It consists of a slide base, cover, harness quick disconnect LPCA 16 Channel with transmit, brass pan head slotted and screw-countersunk head. It is made from the material which attributes good strength, stiffness, density, impact resistance and machinability. The 16 Channel Excite interface MR coils (antennas) from the coil interface connectors through a gain stage to 16 channel RF receivers. The 16 Channel Switch’s control signals and DC power is supplied by the Driver Control Board (DCB) and Multi-Coil TR bias is supplied by the Multi Coil Drive Board (MCDB), which is located in the Universal System Support Subsystem (USSS). It is made from the material which possesses impact resistant, corrosion resistant, ductility, electrical and thermal conductivity. 16-CH Excite-III HNU system cable (P/N: 5582297) has16-RF pin connector and the Test box (P/N: 2412413) has 8-RF pin connector that cannot be used together for programming Coil ID.
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.