text.skipToContent text.skipToNavigation

VCT HD 48V Power Supply 5197802-3-R

5197802-3-R
Refurbished
Computed Tomography (CT)
GE HealthCare
GE HealthCare
Exchange - Return Defective

Core Exchange
Please ship this returnable part back within 30 calendar days of receipt of your original part shipment. Failure to return the part within 30 calendar days will result in an additional charge. We encourage you to check inventory prior to adding this item to your cart.

Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • 180-264 Vac nominal input range
  • Overvoltage, over temp. and short circuit protection
  • Forced Air Cooled
  • Adjustable Output

Product Overview

This power supply assembly includes AC-DC power supply, fuse board, cables, standoff, ferrite core, mounting bracket and moutning hardwares. The AC-DC power supply converts input AC 180-264 with temporary voltage sags down to 165VAC for a time of 30 seconds into 48V DC voltage. It is a 4500 W continuous output power supply which is designed to provide low ripple rectified output. It is fully protected against short circuit, over load, over heating and over voltage. The power supply relies upon forced air cooling for heat dissipation which allows it to work reliably over a wide range of temperatures starting from 0 °C to 40 °C. The power supply is covered with a metal cover to prevent any inadvertent access to live parts and to provide electro-magnetic shielding. This power supply assembly can be used with GE's Discovery CT750, Revolution Discovery CT and Discovery CT Computed Tomography (CT) Systems. 5197802-3-R

Return And Exchange

GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.