text.skipToContent text.skipToNavigation

Patient Handling Power Supply Compatible with Halogen Lights 5215012-2-R

5215012-2-R
Refurbished
Magnetic Resonance Imaging (MRI)
GE HealthCare
GE HealthCare
N/A
Exchange - Return Defective

Core Exchange
Please ship this returnable part back within 30 calendar days of receipt of your original part shipment. Failure to return the part within 30 calendar days will result in an additional charge. We encourage you to check inventory prior to adding this item to your cart.

Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Field Replaceable Unit (FRU)
  • CAN (Controller Area Network) controlled
  • Supports halogen style Patient Alignment Lights
  • Exterior finish is electrically conductive and non-corrosive

Other Buying Options


Condition: New

Product Overview

The Patient Handling Power Supply (PHPS) consists of 2 multiple output power supply modules, a PHPS Control board, a CAN Communication Core (CCC) Board which is physically mounted as a daughter board on the control board and a pulse width modulated Servo amplifier. The PHPS provides non switched/switched DC as well as switched AC power to various entities in the magnet room such as the Scan Room Interface (SRI-3), Physiological Acquisition Controller (PAC), Bore light, Patient Alignment Lights (PAL), Dock motor for vertical table movement and longitudinal motor for lateral table movement. It also supplies switched AC power to the Patient Comfort Module. The CCC board monitors the health of the power supplies ,status of the servo amplifier and communicates this information to the host via the CAN bus.The PHPS module resides on the penetration panel and can be used with GE's Signa HDxt 1.5T Magnetic Resonance Imaging (MRI) Systems. 5215012-2-R

Compatible Products

Signa HD 1.5T

Signa HD 1.5T

Signa HD 3.0T

Signa HD 3.0T

Signa HDx 1.5T

Signa HDx 1.5T

Signa HDx 3.0T

Signa HDx 3.0T

Signa HDxt 1.5T

Signa HDxt 1.5T

Signa HDxt 3.0T

Signa HDxt 3.0T

Return And Exchange

GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.