Patient Handling Power Supply Compatible with Halogen Lights 5215012-2-R
5215012-2-R | |
Refurbished | |
Magnetic Resonance Imaging (MRI) | |
GE HealthCare | |
GE HealthCare | |
N/A | Exchange - Return Defective |
Core Exchange | |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Field Replaceable Unit (FRU)
- CAN (Controller Area Network) controlled
- Supports halogen style Patient Alignment Lights
- Exterior finish is electrically conductive and non-corrosive
Frequently purchased with this item
Product Overview
The Patient Handling Power Supply (PHPS) consists of 2 multiple output power supply modules, a PHPS Control board, a CAN Communication Core (CCC) Board which is physically mounted as a daughter board on the control board and a pulse width modulated Servo amplifier. The PHPS provides non switched/switched DC as well as switched AC power to various entities in the magnet room such as the Scan Room Interface (SRI-3), Physiological Acquisition Controller (PAC), Bore light, Patient Alignment Lights (PAL), Dock motor for vertical table movement and longitudinal motor for lateral table movement. It also supplies switched AC power to the Patient Comfort Module. The CCC board monitors the health of the power supplies ,status of the servo amplifier and communicates this information to the host via the CAN bus.The PHPS module resides on the penetration panel and can be used with GE's Signa HDxt 1.5T Magnetic Resonance Imaging (MRI) Systems. 5215012-2-R
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.