High Voltage (HV) Cable - Anode
5503010-2 | |
New | |
X-Ray | |
GE HealthCare | |
GE HealthCare | |
N/A | Outright |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- RoHS compliant
- It is very low in size
- It has very less capacitance
- More flexible and high bending radius
Frequently purchased with this item
Product Overview
The High Voltage (HV) Cable is used significantly for X-Ray, Computed Tomography (CT) and for angiography equipment. It provides high voltage power supply for the machines. These machines monitor the voltage and regulate it using a voltage regulator according to the requirement. The cable has three 1.8mm conductors and made up of tinned copper wire. There will be fillers around these conductors and covered by semi-conducting tape. Outside the tape there is a high voltage insulation made of Ethylene Propylene (EP) rubber, outside that comes the shielding which has 95% coverage and over that comes the PVC jacket which is the outermost and comes with the details of the cable and the brand name. The cable has special connectors at both the ends that come with tail-casing, nut and washer, which will be plugged into the machine. The connectors are to be assembled and processed as per the recommended procedures. The cable can withstand temperatures ranging from -40°C to 70°C in the operating condition. The cable is HIPOT tested to 94kV for one minute. The cable is used in Digital Imaging (DI) machines like Optima XR220amx, Discovery IGS 740, Discovery XR656, Signa Optima HDxt 23 3.0T, LightSpeed 3.X Ultra 8-Slice, Precision 500D, Definium 5000, Brivo XR285amx, Proteus XR/a, OEC FLUOROSTAR 7900, KM Aero DR Rad, Prestilix and Definium AMX 700, among others.
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.