Drive Gear Snap Assembly

GA200750
5396884 GA200177
Neuf
Ultrasound
LOGIQ E9
GE HealthCare
GE HealthCare
N/A
Outright
Ajouter à la liste de souhaits
Se connecter pour faire des achats
Se connecter pour faire des achats
Veuillez sélectionner la date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Easy to install and dismantle
  • RoHS compliant

Other Buying Options


Condition: Used

Présentation du produit

The Drive Gear Snap Assembly is a part of the Z mechanism. The Z mechanism can be manually repositioned in the event the drive gear is disconnected or has failed or if the power is turned off. The top console can drop unexpectedly when the mechanism is released. Move the handle a few millimeters to the right side to release the Z mechanism and at the same time move the top console up or down as required. In order to install it, mount the drive gear assembly and fasten it with the four screws and connect the cable to the XYZ control box. The cable must be routed under the main cable ground clamp. Power up the ultrasound system and verify that XYZ is functioning as intended and then power it down in order to install the top, left and right side cover. In order to remove it, remove the main cable ground clamp and disconnect the motor cable from the xyz control box. Then unscrew and remove the four fixing screws to pull the unit away.

Produits compatibles

Vivid E9

Vivid E9

Article(s) équivalent(s):

Below is more information on the equivalent item(s). Items without a hyperlink are listed for reference only and are not available for purchase online.

Article(s) équivalent(s)Nom du produit
5396884

5396884

GA200177

GA200177

Return And Exchange

GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion. 

  • Mes articles récemment vus
  ‹ ›