E-PSM(P) Non-invasive Blood Pressure (NIBP) Pump
M1221540 | |
M1011858 | |
New | |
Patient Monitoring | |
GE HealthCare | |
GE HealthCare | |
N/A | Outright |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Easy to Remove
- Easy to installation
- Earth grounded
Frequently purchased with this item
Product Overview
E-PSM (P) Non-invasive Blood Pressure (NIBP) Pump is used in the pneumatics of the patient side module. The patient side module and accessories are used for monitoring hemodynamic parameters for patients. The air pump is used for pumping the measuring pressure of the cuff and the intake air filter for preventing dust and other parts from entering the air pump and the valves. The pump is properly grounded to prevent earth leakage, a rubber pin of a pump bottom cover is inserted into a sinking of a ground contact. Connect an external mercury manometer with a pump to the module through the both tubes of the hose. The pump allows up to 200 mmHg pressure (range of 150 to 300 mmHg allowed) according to the manometer. Verify that both pressure values in the prompt field match the manometer reading, if not adjust by turning the ComWheel. The module automatically pumps a pressure of 260 mmHg in the cuff. Wait for several seconds until the pressure stabilizes, then check that the pressure reading does not drop more than 6 mmHg per minute. The hemodynamic parameters comprise NIBP, temperature, impedance respiration and arrhythmia. NIBP is an indirect method for measuring blood pressure. E-PSM(P) module are necessary parts to measure NIBP measurement.
Equivalent Item(s):
Below is more information on the equivalent item(s). Items without a hyperlink are listed for reference only and are not available for purchase online.
Equivalent Item(s) | Item Details |
---|---|
M1011858 | ASSY-HKI, PUMP UNIT, E-PSM, Manufacturing assembly - Make |
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.