Consolidated Ventilator Interface Board Sub Assembly

M1223654
Neuf
Administration d'anesthésie
GE HealthCare
GE HealthCare
Outright
Ajouter à la liste de souhaits
Se connecter pour faire des achats
Se connecter pour faire des achats
Veuillez sélectionner la date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • High performance Consolidated Ventilator Interface Board (cVIB) assembly
  • Voltage range 12 VDC
  • High performance Atmel® ATMEGA16 microcontroller
  • Equipped with electronic circuit breaker protection

Présentation du produit

The Consolidated Ventilator Interface Board (cVIB) Assembly is a specially designed control board intended for use in Avance™ and Aisys™ anesthesia system. The assembly is comprised of the Consolidated Ventilator Interface Board (cVIB), colored couplings (white, black, blue, yellow), sleeves, a tube and label. The cVIB is referred as Central Processing Unit (CPU) of the anesthesia system and it interfaces with the ventilator of the Anesthesia Control Board (ACB). The ventilator interface section of the board is managed by an Atmel® ATMEGA16 microcontroller. The interface board controls the switches and components such as the inspiratory and expiratory flow transducers, patient airway and manifold transducers, airway over-pressure, oxygen sensor, ABS switches, ACGO switches, bag/vent switch, O₂ flush switch, gas inlet valve, inspiratory flow valve, pipeline pressure transducers, cylinder pressure transducers, mixer, vaporizer, task Light and machine on/standby switch.

Produits compatibles

Aisys

Aisys

Avance CS2

Avance CS2

Aisys CS2

Aisys CS2

Return And Exchange

GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.