O-ring - 51.1 OD 44.04 ID BCG 3.53 W Silicone 50 Durometer
1407-3507-000 | |
Neuf | |
Administration d'anesthésie | |
GE HealthCare | |
GE HealthCare | |
N/A | Outright |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Resistant to extreme temperatures
- Withstands extreme weather conditions
- Minimal lubrication with Krytox® is sufficient
- High Temperature Usage: Up to 480° F
Fréquemment acheté avec cet article
Présentation du produit
The O-ring is used to prevent leakage of vapors from Breathing Circuit Gas (BCG) in an anesthesia delivery machine. The O-ring mounted on vaporizer ports ensures consistent gas flow through the breathing circuit. In case of a leak in the vaporizer, the anesthesia delivery machine can function normally if the vaporizer remains switched off. But on switching on the vaporizer, the fresh gas flow is reduced with little or no vapor. A common cause of vapor leakage is the absence of O-ring or a damaged O-ring. The O-ring provides sealing to the vapors in BCG thus avoiding ambient gases mixing with vapors. It is made of silicone rubber which is an excellent seal for high temperatures in static applications. Silicone compounds are widely used in medical applications because they are very clean and odorless or tasteless. It has a good insulating properties.
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.