Twin Gradient Switch Box 2253466-R

2253466-R
Refurbished
Magnetic Resonance Imaging (MRI)
GE HealthCare
GE HealthCare
N/A
Exchange - Return Defective

Core Exchange
Please ship this returnable part back within 30 calendar days of receipt of your original part shipment. Failure to return the part within 30 calendar days will result in an additional charge. We encourage you to check inventory prior to adding this item to your cart.

Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • No Manual Field Calibration Required
  • Mean Time Before Failure of more than 20000 Hours
  • With Safety Labels
  • EMC Design

Other Buying Options


Condition: New
Condition: Used

Product Overview

The Gradient Switch is part of the Twin-Gradient GEMINI project. Its function is to switch between the twin Coils (WB= Whole Body and ZM= ZooM gradient) under the command of the Operator or the Host Computer. The switching is done mechanically by Contactors. These contactors can carry currents up to 400A and have insulation of 1500V. There are 6 contractors: 3 for WB and 3 for ZM. The Commands are sent through Opto-Couplers and SSR (Solid State Relays) to keep good isolation between Commands and the Gradient currents. The assembly is installed in a special cabinet, on the way from the Gradient Amplifier to the Gradient Filter (on the Penetration Panel). The Unit in its communication to the GP (Gradient Processor) also send the Contactors Status and Diagnostic information for Faults. The whole Unit is designed to be mounted in a Rack 19 inches Standard : 6U Height, 36 inches depth. This Twin Gradient Switch is compatible for use with GE's Signa 3.0T HDxt and Signa 1.5T HDxT Magnetic Resonance Imaging (MRI) Systems. 2253466-R

Return And Exchange

GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.