Collimator Motor -Gold Contact and Coupling Assembly 5271284-3-R
| 5271284-3-R | |
| Refurbished | |
| Computed Tomography (CT) | |
| GE HealthCare | |
| GE HealthCare | Exchange - Return Defective |
|
Core Exchange | |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- Highly compatible
- Manual shaft adjustment in the motor
- Coupling with helical double start technology
- Higher torque capacity
Product Overview
The Collimator Motor with Gold Contact and Coupling Assembly consists of the single piece made Aluminum Coupling and MDrive23Plus Micro stepping high torque integrated motor. The integrated electronics of the MDrive23Plus eliminates the need to run motor cabling through the machine, reducing the potential for problems due to electrical noise. Due to innovative techniques used to control current flowing through the motor, resonance is significantly dampened over the entire speed range, and audible noise is reduced. The MDrive23Plus is a compact, powerful and inexpensive solution that will reduce design and assembly time for a large range of brushless motor applications. This MDrive motor connects with DS (Double Start) series beam couplings are a low inertia, high performance coupling that utilize a helical double start technology. The DS Series coupling used for optimized motion control systems. This Series contains two helical beams (double start) with two separate HELI-CAL Flexures (double flexure), combining greater end-to-end rotational accuracy with radial flexibility in single design. It uses only integral clamp attachments. This assembly is packed with 0.25 in HEX bit and document contains information for coupling replacement and important notes for VCT Collimator Cam Motor.
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.
Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.



